/  SOLUTION

/  HYUNDAI ELECTRIC

/  INDUSTRIAL SOLUTION

ESSENTIAL FOR TODAY

POTENTIAL FOR TOMMOROW

INDUSTRIAL SOLUTION

Hyundai electric • Empower Growth

LV & MV SWITCHGEAR • HYUNDAI ELECTRIC

Hyundai Electric manufactures high-performance, high-reliability based on IEC and ANSI certified switchgear and has the largest supply record in the domestic industrial plant market, ranging from various types of buildings to plants, including nuclear power plants.

We manufacture various types of switchgear including gas-insulated switchgear cubicles, gas-insulated switchgear units, high/low-voltage switchgear, motor control panels, etc. with key features such as customizable designs, long lifetime, and minimal maintenance requirements.

  • High reliability and arc safety                                      • Long lifetime and minimal maintenance requirements
  • Compact and customizable optimized design         • Standardized design for high compatibility
  • Extensive supply record

FEATURES

DESCRIPTION

 

MV SWITCHGEAR  |  HMS

LV SWITCHGEAR  |  HiMCC

36 / 38kV

24kV

17.5kV

12kV

7.2kV

HMS -N36

 

Applicable Standards

IEC 62271-200

Breaking Capacity

~ 31.5kA/3s

Rated Voltage

36kV

Features

~

Rated Current

1,250/2,000/2,500/3,150A

HMS -A38

 

Applicable Standards

ANSI/IEEE C37.20.2

Breaking Capacity

~ 40kA/3s

Rated Voltage

38kV

Features

~

Rated Current

1,200/2,000/3,000A

HMS -N24

 

Applicable Standards

IEC 62271-200

Breaking Capacity

~ 31.5kA/3s

Rated Voltage

24kV

Features

Miniature

Rated Current

1,250/2,000/2,500/3,150A

HMS -N17.5

 

Applicable Standards

IEC 62271-200

Breaking Capacity

~ 50kA/3s

Rated Voltage

17.5kV

Features

General

Rated Current

1,250/2,000/3,150/4,000A

HMS -N17.5C

 

Applicable Standards

IEC 62271-200

Breaking Capacity

~ 50kA/3s

Rated Voltage

17.5kV

Features

Miniature

Rated Current

1,250/2,000/3,150/4,000A

HMS -A15

 

Applicable Standards

ANSI/IEEE C37.20.2

Breaking Capacity

~ 40kA/3s

Rated Voltage

15kV

Features

Two-phase Load

Rated Current

1,200/2,000/3,000

HMS -N12

 

Applicable Standards

IEC 62271-200

Breaking Capacity

~ 50kA/3s

Rated Voltage

12kV

Features

~

Rated Current

1,250/2,000/3,150/4,000A

HMS -N12C

 

Applicable Standards

IEC 62271-200

Breaking Capacity

~ 50kA/3s

Rated Voltage

12kV

Features

Miniature

Rated Current

1,250/2,000/3,150/4,000A

HMS -N7.2

 

 

Applicable Standards

IEC 62271-200

Breaking Capacity

~ 50kA/3s

Rated Voltage

7.2kV

Features

~

Rated Current

1,250/2,000/3,150/4,000A

HMS -N7.2D

Applicable Standards

IEC 62271-200

Rated Voltage

7.2kV

Rated Current

1,250/2,500

Breaking Capacity

~ 40kA/3s

Features

~

HMS -A5

 

Applicable Standards

ANSI/IEEE C37.20.2

Breaking Capacity

~ 50kA/3s

Rated Voltage

4.76kV

Features

Two-phase Load

Rated Current

1,200/2,000/3,000

Basic Switchgear (Metal-Enclosed)

HLS -LV

 

Applicable Standards

IEC 62271-200

Breaking Capacity

~ 85kA/1s

Rated Voltage

~ 660V, 50 to 60Hz

Features

3-Phase Loadable

Rated Current

~ 5,000A

Multi-Panel MCC

H8PU-L1

 

Applicable Standards

IEC 62271-200

Breaking Capacity

~ 85kA/1s

Rated Voltage

~ 660V, 50 to 60Hz

Features

3-Phase Loadable

Rated Current

~ 4,000A

Load Center

HLS-LC

 

Applicable Standards

ANSI C37.20.1, C37.50 & C37.51

Breaking Capacity

~ 50kA/1s

Rated Voltage

~ 440V, 50/60Hz

Features

2-Phase Loadable

Rated Current

800/1,600/2,000/ 3,000/4,000A

For detailed specifications & more information of

LV & MV Switchgear, please contact our representative.

Request for  technical product

Request for PRODUCT PRICELIST

LV & MV CIRCUIT BREAKERS • HYUNDAI ELECTRIC

Hyundai Electric has a diverse product family of  Low & Medium Voltage circuit breakers, from MCCBs for use in homes to ACBs and VCBs for industrial plants.

Our high-quality products safely protect your electrical equipment. The new HG Series has won several design awards, including the ‘iF Design Award 2016’, for its compact, sophisticated designs.

  • Variety of Product ; Wide range of uses, from residential to general industrial equipment and plants
  • Product of Safety ; Greater Stability

FEATURES

DESCRIPTION

 

Molded Case

Circuit Breaker

(MCCB)

Earth Leakage

Circuit Breaker

(ELCB)

Magnetic

Switch

(MS)

Air

Circuit Breaker

(ACB)

Vacuum

Circuit Breaker

(VCB)

Miniature

Circuit Breaker

 (MCB/RCCB)

 

Features

  • Maximized selectivity with a wide product range
  • Enhanced safety with higher breaking capacity
  • Adjustable ratings applicable for all AFs

 

Specification

  • M15A ~ 1600A, 5kA ~ 150kA
  • Ui = 1000V, Ics = 100%Icu
  • Adjustable ratings applicalbe for all AFs

 

 

Features

  • Maximized selectivity with a wide product range
  • Enhanced safety with higher breaking capacity
  • Compatible size and internal parts with MCCB

 

Specification

  • 15A ~ 800A, 2.5kA ~ 85kA
  • Ics = 100%Icu
  • Adjustable rated residual operating current: 100 - 300 - 500 - 1000 (mA)
  • Time-delay type Limiting non-actuating time : 0 - 0.2s - 0.5s - 1s

 

 

Features

  • Provides motor protection solution applicable for various industrial systems with enhanced durability and insulation performance,
  • Decreased installing space by upper arrayed structure of Auxiliary Contacts
  • Auxiliary Relay with reduced power consumption type
  • Direct mounting structure for Thermal Overload Relay

Specification

  • Various product ranges : 9 ~ 800A (8 frames)
  • Rated Insulation voltage : 1000V (50A ~ )
  • AC/DC free voltage (115A ~ )

 

Features

  • High breaking capacity, advanced protection trip relay (OCR) and various accessories
  • Multiple terminal busbar connections
  • 100% conventional thermal current of N phase

Specification

  • UAS 1600/3200 2 types AF
  • UAN 2000/4000/5000/6300 4 types AF

 

Features

  • Wide product range and improved user convenience
  • Various control voltage and mounting type
  • Certified reliability and stability by international standard IEC 62271-100
  • Simple structure and convenient maintenance : VI condition can be easily checked from outside of the pole part

Specification

  • 7.2/12/17.5 kV, up to 50 kA, up to 4000 A
  • 24 kV, up to 40 kA, up to 3150 A
  • 36 kV, up to 40 kA, up to 3150 A

 

Features

  • WMaximized selectivity with a wide product range
  • Current limiting structure
  • Various accessories (AUX, ALT, SHT, UVT, Handle lock)
  • Double terminal connection by cable or bus bar
  • Clear ON/OFF indicator

Specification

  • Up to 10kA at AC 240/415V
  • B,C,D curve
  • Rated current : up to 125A
  • Rated residual current : 10, 30, 100, 300, 500mA

For detailed specifications & more information of

LV & MV Circuit Breakers, please contact our representative.

Request for  technical product

Request for PRODUCT PRICELIST

INDUCTION MOTORS • HYUNDAI ELECTRIC

Hyundai Electric manufactures a wide range of high-voltage motors, providing our customers with the best motor for their environment and operating conditions. Our high-voltage motors comply with international standards such as IEC, NEMA, etc. and also are manufactured using state of the art design technology and rigorous production quality control system. So they show stable performance in various industries including specialized environments such as nuclear power plants, desalination plants, etc.

  • Complies with international standards (IEC, NEMA, ANSI, DIN, etc.)
  • Supplied to various industries, including power plants, desalination, ship building, off shore, oil & gas, water treatment, nuclear, etc.
  • Internationally certified explosion-proof products available
  • Superior performance with high efficiency, low vibration, and low noise
  • Stable operation even in the toughest operating conditions
  • Robust design suitible for frequent starting and high-inertia application

FEATURES

DESCRIPTION

 

LOW VOLTAGE

INDUCTION MOTOR

MEDIUM & HIGH VOLTAGE

INDUCTION MOTOR

MOTOR FOR HAZARDOUS

AREA APPLICATION

Type

Output Range

 Voltage

Frequency

Number of Poles

Protection Level

Insulation Class

Totally Enclosed Fan Cooled / TEFC

Cast Iron Frame Motor

 

0.75 - 450 kW

(1 - 600 HP)

~ 600V

50 Hz, 60Hz

2, 4, 6, 8

IP 44, 54, 55

B, F

Totally Enclosed Fan Cooled / TEFC

Aluminum Frame Motor

 

0.2 - 7.5 kW

(0.3 - 10 HP)

~ 600V

50 Hz, 60Hz

2, 4, 6, 8

IP 44, 54, 55

B, F

Totally Enclosed Fan Cooled / TEFC

High Efficiency Motor

 

0.2 - 375 kW

(0.3 - 500 HP)

~ 600V

50 Hz, 60Hz

2, 4, 6, 8

IP 54, 55

F

Output Range

Type

Number of Poles

 Voltage

Protection Level

Insulation Class

Frequency

Drip-proof Motor

 

0.75 - 2000 kW

(1 - 250HP)

~ 600V

50 Hz, 60Hz

2, 4, 6, 8

!P 22, 23

B, F

Marine Motor

 

0.4 - 450 kW

(0.5 - 600 HP)

~ 600V

50 Hz, 60Hz

2, 4, 6, 8

IP 44, 54, 55

B, F

Inverter Shield Motor

 

0.75 - 3750 kW

(1 - 500 HP)

~ 600V

50 Hz, 60Hz

2, 4, 6

IP 54

B, F

IEE841 Motor

 

0.75 -200 kW

(1 - 250 HP)

~ 600V

50 Hz, 60Hz

2, 4, 6

IP 55

B, F

Type

Output

Range

Model

Frequency

Number of Poles

Voltage

Totally Enclosed Fan

Cooled - Squirrel

Cage Rotor

 

HL E6

110 - 1.100 kW

2 - 11kV

50 / 60 Hz

2 - 18 Poles

Totally Enclosed Air

to Air Cooled - Squirrel

Cage Rotor

 

HI Q1 (4 Poles~),

HR Q3 (2 Poles)

830 - 16.000 kW

2 - 14kV

50 / 60 Hz

2 - 32 Poles

Open Drip

Proof - Squirrel

Cage Rotor

 

HI A1 (4 Poles~),

HR A3 (2 Poles)

1.030 - 21.600 kW

2 - 14kV

50 / 60 Hz

2 - 32 Poles

Totally Enclosed Water

to Air Cooled - Squirrel

Cage Rotor

 

HI N1 (4 Poles~),

HR N3 (2 Poles)

1.030 - 21.600 kW

2 - 14kV

50 / 60 Hz

2 - 32 Poles

Totally Enclosed Air

to Air Cooled - Squirrel

Cage Rotor (Vertical)

 

HR Q3

810 - 11.390 kW

2 - 14kV

50 / 60 Hz

4 - 32 Poles

Type

  • Vertical mounting is available as an option
  • Motors exceeding the following specification are available as an option.

Output

Range

Model

Frequency

Number of Poles

Voltage

Weather

Protected I/II - Squirrel

Cage Rotor

 

HI P1 (4 Poles~),

HR P3 (2 Poles)

1.030 - 21.600 kW

2 - 14kV

50 / 60 Hz

2 - 32 Poles

Weather

Protected I/II - Squirrel

Cage Rotor (Vertical)

 

HR P3

1.030 - 14.520 kW

2 - 14kV

50 / 60 Hz

2 - 32 Poles

Open Drip

Proof -

Wound Rotor

 

HR S3

250 - 18.000 kW

2 - 14kV

50 / 60 Hz

4 - 12 Poles

Totally Enclosed Air

to Air Cooled -

Wound Rotor

 

HR V3

350 - 7.500 kW

2 - 14kV

50 / 60 Hz

4 - 12 Poles

Non - Sparking (Ex nA) -

Squirrel Cage Motor

 

Type

 

Flame Proof (Ex d) -

Squirrel Cage Motor

 

Pressurized Enclosure (Ex p) -

Squirrel Cage Motor

Output Range

110 - 4,770 kW

1030 - 21,600 kW

110 - 21,600 kW

Voltage

2 - 13.8 kV

2 - 14 kV

2 - 14 kV

Number of Poles

2 - 16 Poles

2 - 32 Poles

2 - 32 Poles

LOW Voltage Induction Motor

Enclosure

Certificates & Type of Protection Categories

HL-XD

ATEX (Baseefa), PTB : Ex d

HL-XN

ATEX (Baseefa) : Ex nA

XK, XKS, XKP

XL, XLS, XLP

c UL : Class 1, Division 1 Group C&D

PK, PKS, PKP

PL, PLS, PLP

CSA C US : Class 1, Division 2 Group A, B, C, D

Class 1, Zone 2 Group IIA, IIB, IIC

HK-XP, HL-XP

KOSHA, KGS : Ex d, Ex e

Medium & High Voltage Induction Motor

Enclosure

Certificates & Type of Protection Categories

TEFC (IC411)

ATEX (Baseefa) : Ex nA, Ex d IIB, IIC; PTB  : Ex d

CSA : Class 1 Division 2 / Zone 2

KOSHA, KGS : Ex nA, Ex e, Ex d

TEAAC (IC511)

ATEX (Baseefa) : Ex nA, Ex d IIB

CSA : Class 1 Division 2 / Zone 2

KOSHA, KGS : Ex nA, Ex e

TEAAC (IC611)

ATEX (Baseefa) : Ex nA, Ex p

CSA : Class 1 Division 2 / Zone 2

KOSHA, KGS : Ex nA, Ex e, Ex p

TEWAC (IC81W)

ATEX (Baseefa) : Ex nA, Ex p

KOSHA, KGS : Ex nA, Ex e, Ex p

WP II

CSA : Class 1 Division 2 / Zone 2

For detailed specifications & more information of

Induction Motors, please contact our representative.

Request for  technical product

Request for PRODUCT PRICELIST

AC DRIVES • HYUNDAI ELECTRIC

 

DESCRIPTION

Hyundai Electric optimizes process efficiency and availability of industry and implements factory automation systems by providing versatile and high-quality AC drive. AC drive from Hyundai-Electric incorporate the latest technology for High-power quality, and have been designed with a user-friendly interface for easy operation.

FEATURES

  • High-power Characteristics for efficiency and power factor
  • Excellent durability and wide output range
  • Trip-Free Operation by optional function
  • Excellent performance for Speed of response and Torque Control
  • Easy maintenance

LOW VOLTAGE

AC DRIVE

MEDIUM VOLTAGE

AC DRIVE

N 800S

 

N 800A

 

N 700E

 

N 700

 

Type

Voltage Class

Max. Applicable Motor (4 Poles, kW)

Rated Output Current (A)

Rated Output Voltage (V)

Output Frequency Range

NS 800S

220V Class

440V Class

0.37 - 22.0 (HD)

0.37 - 132.0 (HD)

2.4 - 88.0 (HD)

1.3 - 251.0 (HD)

1-phase / 3-phase

0 - 240V (corresponds to receiving voltage)

3-phase

0 - 480V (corresponds to receiving voltage)

0 - 320 Hz

0 - 320 Hz

NS 800A

220V Class

440V Class

0.37 - 75.0 (HD)

0.75 - 250.0 (HD),

1.1 - 315.0 (LD)

2.6 - 251.0 (HD)

2.6 - 520.0 (HD),

3.4 - 590.0 (LD)

3-phase

0 - 240V (corresponds to receiving voltage)

 3-phase

0 - 500V (corresponds to receiving voltage)

0 - 320 Hz

0 - 320 Hz

Type

Voltage Class

Max. Applicable Motor (4 Poles, kW)

Rated Capacity (kVA) 480V

Rated Output Current (A)

Rated Output Voltage (V)

Output Frequency Range

NS 700E

220V Class

440V Class

0.4 - 22.0 (HD)

0.4 - 350.0 (HD)

9 - 90.0 (HD)

1.8 - 656.0 (HD)

240; 1.2 - 37.4 (HD)

480V; 1.5 - 500.0 (HD)

3-phase

0 - 240V (corresponds to receiving voltage)

3-phase

0 - 480V (corresponds to receiving voltage)

0.01 - 400 Hz

0.01 - 400 Hz

NS 700

220V Class

440V Class

5.5 - 55.0 (HD)

5.5 - 132.0 (HD)

24 - 220.0 (HD)

12 - 260 (HD)

240V; 9.9 - 91.4 (HD)

480V; 9.9 - 216.1 (HD)

3-phase

0 - 240V (corresponds to receiving voltage)

3-phase

0 - 480V (corresponds to receiving voltage)

0.01 - 400 Hz

0.01 - 400 Hz

 

 

Voltage Class

Output Rating (kVA)

Shaft Output (kW)

Input Main Circuit

Input Control Circuit

Output Frequency (Hz)

Power Factor / Efficiency of Main Power

Main Protection Features

Data Communication

Main Reliability Features (optional)

Application Loads

Applicable Standards

FD fan, ID fan, dust-collecting blower, circulation pump, compressor, acetic acid pump, extruder, mixer, non-regenerative loads such as turbine generators, etc.

Cell By-pass, Redundant controller, Redundant control power supply, Fly restart, Ride through after voltage dip, Synchronous transfer

Modbus RS485/232 (Default), Ethernet (optional), Profibus-DP (optional)

Current limit, overcurrent, overvoltage, overload, undervoltage, output ground-fault, CPU error, cooling fan error, control power loss

Approximately 95% or above (at normal operating speed) / approximately 97% (including transformer)

0 ~ 120Hz

3-phase 220V, 440V, etc., 50/60 Hz, DC 110V

3-phase 3300V / 4160V / 6600V / 11000V / 13800V, 50/60 Hz

155 ~ 3200

155 ~ 3200

155 ~ 3200

155 ~ 3200

155 ~ 3200

155 ~ 3200

200 ~ 4000

200 ~ 4000

250 ~ 5000

660 ~ 13300

400 ~ 8000

800 ~ 16000

3300V

3300 V

3300V

11000V

6600 V

13800 V

IEC, KS, IEEE, CE

For detailed specifications & more information of

AC Drives, please contact our representative.

Request for  technical product

Request for PRODUCT PRICELIST

Reach us :

 

sales@armasindo.co.id